GAS LEAK DETECTORS – GAS LEAK CONTROL SHUT-OFF SYSTEM AND FIRE CONTROLS
Agility Engineering-Tech Co., Ltd. keeping stock of Gas Detectors – Gas Leak Shut-Off Systems and Fire controls, Brand Name: “Shin Woo” South Korea.
SAFETY IS OUR DUTY.
These Gas detectors and controls are Safety products – detect any LPG-CNG-BUTANE and METHANE gas leakages and gives Alarm as well provide output signal to Gas Leak Shut-Off system through Controller and save life’s, property and keep healthy environment.
Shin Woo has developed high qualified and multi-functional safety system products that foster the safe and convenient conditions in livings.
Gas detectors are manufactured for two types of uses:
- Home Use (Houses, Schools and Condominiums) – Commercial Use
- Industrial Use
All are detachable gas detectors designed to prevent accidents due to gas leak in places where combustible gases (LNG, LPG, etc.) at commercial and industrial places.
Commercial Use Gas detectors are: Models: ND-103 (DC 12V Supply), ND-102D/F (DC 12VSupply), ND-112 (DC 12 V Supply) / ND-114 (AC 220V 50/60Hz Supply), & ND-104N/R(AC 220V 50/60Hz Supply)
Industrial Use Gas detectors are: All Power supply: AC 220V 50/60Hz : Models: Detection Part : EX-2B (T-300) – Flameproof Enclosure (EX d IIB T4) Receivers: ND – 200 ( 1-Channel) , ND – 205B ( 1-Channel) — Suitable for LNG – LPG
Detection Part: ND – 210 – Design to measure Gases – NH3, CL2, CO2, HF, SO2, etc. Receiver Part: ND – 213 (3, 6 and 9 – Channels) – Also Suitable for LND – LPG
Gas Leak Alarm Shut-Off system (Detection and Control Parts): Gas Detection – Alarm – GSV – 102M(V4) & GSV – 102T — Both AC220V 50/60Hz Gas Detection – Alarm – GSV – 102W – AC 80 to 250 V 50/60Hz
Control Part: GSV – 103M(V2) –AC100 to 240V 50/60Hz– Remote & manual Operation. Control Part: GSV – 182 – AC100 to 240V 50/60Hz Control Part: GSV – 200M – AC 220V 50/60Hz – 9 Channels Control Part: GSV – 201 – AC 220V 50/60Hz – 1 to 6 Channels Control Part: GSV – 303 –AC 220V 50/60Hz, KSC3304, 1.5m W/Plug –1 to 3 Channels Main Controller – Gas Leak Alarm Shut-Off – AC 220V 50/60Hz – 9 – Channels
For Natural Gas vehicles (CNG – NGV) – CNG Detection Part: Power supply 24VDC Receiving Part: Power supply 24VDC – 1 to 3 Channels
Gas Leak Alarm Shut-Off system (Shut-Off Parts): Shut-Off Part: SV – 20A, 25A – Input Signal: DC 12V+/-30% – Geared Motor Lever Type Shut-Off Part: SV – 20B – Input Signal: DC 12V+/-30% – Geared Motor Lever Type Shut-Off Part: SV – 20H – Input Signal: DC 12V+/-30% – Geared Motor Ball Valve Type Shut-Off Part: SV 32A to 65A – Input Signal: DC 28V+/-30% – Geared Motor Lever Type Shut-Off Part: SV 80A & 100A–Input Signal: DC 34V+/-30% -Geared Motor Lever Type Shut-Off Part: SV125A & 150A–Input Signal: DC 34V+/-30%-Geared Motor Lever Type Shut-Off Part: SV200A To 500A–Input Signal: DC 36V+/-30%-Geared Motor Pressure Gauge-Receiving Part-Control Box: TP-500 – AC220V 50/60Hz Pressure Gauge Part: 1, 2, 5, 10, 15 & 20Kg/cm2 – Flameproof Enclosure EX d IIB T4
Gas Leak Alarm Shut-Off Parts Sizes and Torque Information:
SV–20, 25A -Suitable to Ball Valve Lever type 3/4” (20A) & 1” (25A)–Torque 65 kgf. Cm
SV–20B-Suitable to Ball Valve Lever type 3/4” (20A) – Torque 65 kgf. Cm
SV–20H -Suitable to Ball Valve Direct to Spindle 3/4” (20A) – Torque 65 kgf. Cm
SV–32A & 40A for Ball Valve Lever 1-1/4” (32A) & 1-1/2” (40A) – Torque 1400 kgf. Cm
SV–50A & 65A for Ball Valve Lever 2” (50A) & 2-1/2” (65A) – Torque 1900 kgf. Cm
SV–80A & 100A for Ball Valve Lever 3” (80A) & 4” (100A) – Torque 2800 kgf. Cm
SV–125A & 150A for Ball Valve Direct 5” (125A) & 6” (150A) – Torque 11000 kgf. Cm
SV–200A for Ball Valve Direct 8” (200A) – Torque 13000 kgf. Cm
SV–250A & 300A for Ball Valve Direct 10” (250A) & 12” (300A) – Torque 20000 kgf. Cm SV–350A & 400A for Ball Valve Direct 14” (350A) & 16” (400A) – Torque 27000 kgf. Cm
SV–500A for Ball Valve Direct 20” (500A) – Torque 35000 kgf. Cm
Portable Gas Detectors:
SD-1000N – for LPG, LNG, H2 – LCD Display – normal Battery AAA 1.5V x 3pcs
SD-1000R–for LPG, LNG–LCD Display -Ni-Cd Battery 1.2V–6 pcs
SD-2000–for LPG, LNG–LED Display -Ni-Cd Battery 1.2V–6 pcs
SD-3000 – for LPG, LNG, Ammonia, Hydrogen LED Display -Battery 1.2V–6 pcs
SD-4000C – for CO Gas LCD Display -Battery AAA-1.5V–3 pcs
Portable Gas detector:
MIRICO – S. Korea make – MR-103H – Only Detectable -LPG, Methane, Buane
AUTOMATIC FIRE EXTINGUISHER
Fire Signal Receiver / Controller:
- AC 220V 50/60Hz (6.1 W), RS-485, PLC External Communication Module
Fire Controllers:
- Model: 2050, 1020 and 3000, LED Text Display
Fire Detectors:
- Model: AFE-1020 & SAF-9300 – Power: DC 12 to 18V, LPG, LNG – Diffusion type
Fire Detector / Spray Nozzle:
- Temperature Sensor type, Restorable Type
- Operating temperature 100Deg C
0.6 Liter Fire Extinguisher:
– Press Pin Pressing type, Tank: STS 304
Shut Down Parts: SV-20H, SV-20E, SV-20MA
Other Products:
- Garbage Processor Unit — SGP-1100W/R
- Medical Tooth Sterilizing Apparatus Unit – SUV-1000/W-R, SUD-1100A
- Ultrasonic Cleaner – SUD-2200 (Built-In), SUD-1000 (Home Use), SUD-7509A & 7512A (Restaurant Use)
- Calibration Gas: Methane, Propane and Isobutane – LPG/Town Gas -960 ml each
- Combustible Catalytic Gas sensors
- Photoelectric Smoke sensor SSD-110
- Fixed temperature Fire detector SFT-102, SFT-103
- Door Switch BSM-101
- Emergency Switch SW-2001
Get in Touch
81, Sukhumvit Soi-85, Sukhumvit Road, Bangchak, Thailand, 10260
+66 2 311 5761 | 66 2 311 5762 | 66 2 311 5763
madhusudan.thakor@gmail.com
aicl@hotmail.com